Spectral Measurement (formerly Prism Sound) dScope M1 Advanced I/O family for dScope software
Overview:
Spectral Measurement dScope M1: analogue and digital audio test system
Comprehensive audio testing & analysis for analogue, digital electronics and transducers!
dScope M1 software is now modular!
Buy only the software you need - see the table below for details.
Maximum analyzer sample rate now 768kHz, bandwidth > 200kHz. Analyzer inputs now with +48V or CCP phantom power for microphones. Residual THD+N is significantly improved.
Automate dScope M1 without coding with "Auto Sequence"! Or use our AutoTestSQL app, Labview or other software applications in C++/C#, Python or other language!
Generate professional looking reports in html or PDF formats!
dScope Series III software now updated for the latest Windows 10 releases.
dScope Series III Software:
The dScope M1 interface requires the latest version 1.50 of the dScope Series III software supporting both the original dScope Series III System Units and the new dScope M1 family interfaces. dScope M1 is a new addition to the range of hardware interfaces for the Spectral Measurement dScope Series III audio test and measurement software. It requires an updated version of the dScope Series III software supporting both the original dScope Series III System Units and dScope M1 family interfaces.The updated dScope Series III application is compatible with Windows software from Windows XP to the current Windows 10 in 32 or 64-bit editions.
Please refer to general dScope Series III pages for general description of software capability.
dScope M1 family Hardware interface choices:
The dScope M1 hardware interface is available in several variants, complemented by a number of software variants based on license files that may be purchased to enable feature options.Feature\Model | dScope M1/M1E | dScope M1D | dScope M1HP |
Phantom power, User selectable +48V OR CCP | |||
Switchable Input impedances >100K,600R | 100K Only | 100K,600R | 100K,600R |
Switchable Output impedances (note: 150/200R jumper selected) | 50R,150/200R,floating 50R,150/200R | 50R,150/200R,600R | 50R,150/200R,600R |
Wordclock sync I/O for Digital Outputs | |||
Maximum Generator level on Analogue Outputs | 26dBu - Minimum load 1kohm With 600R load Maximum output is 10Vrms/+22dBu |
26dBu - Minimum load 1kohm With 600R load Maximum output is 10Vrms/+22dBu |
28dBu - Minimum load 2kohm With 600R load Maximum output is 10Vrms/+22dBu |
dScope Series III Software capabilities for the M1 hardware interface family:
The dScope Series III Software is updated for the M1 range of measurement interfaces but also supports the dScope Series III System Unit in its several versions. For more details see the dscope Series III features page.dScope Series III M1-family Online configurator and pricing tool
Software features for the M1 range can now be ordered individually - for example upgrading from 2 to 40 FFT Detectors, or using the extended Generator functions such as User defined waveforms. Call us to discuss your specific requirements or visit our online configurator tool:https://www.spectralmeasurement.com/pages/configurator/
The following table illustrates the capabilities for the range of standard software and hardware configurations for the M1 family.
Option | dScope Series III M1 Interface | |||
dScope Series IIIM1 | dScope Series IIIM1E | dScope Series III M1HP | dScope Series III M1D | |
Analogue I/O sampling rates 48kHz/96kHz/192kHz |
||||
Analogue I/O sampling rates 384kHz |
S/W Option: DSM-O384 for Analogue I/O to fs=384kHz |
|||
Analogue Analyzer sampling rate to 768kHz | S/W Option: DSM-O768 for Analyzer to fs=768kHz |
S/W Option: DSM-O768E for Analyzer to fs=768kHz |
||
Sound Card I/O | ||||
Signal Analyzer (Ampl/Freq/Phase) | ||||
Continuous Time Analyzer (Ampl/THD+N/IMD etc) | ||||
FFT Analysis | ||||
Impulse Response Tests | ||||
Scripting | ||||
Multi-tone Gen/Analysis | S/W Option: DSM-OMTG |
|||
FFT Detectors | 40 | 2 or 40 with S/W Option: DSM-OFFTD40 |
40 | 2 |
Scripted FFT Detectors | S/W Option: DSM-OFFTDS |
|||
Nest/Sense sweep, script on sweep step, plot I/P on X axis | S/W Option: DSM-OXS |
|||
Regulation | S/W Option: DSM-OREG |
|||
Integrated GPIO switchable up to 4 lines Currently pending release |
S/W Option as M1E | S/W Option: DSM-OGPIO |
||
Integrated VSIO for I2S (single wire each way + clocks) Currently pending release |
S/W Option as M1E | S/W Option: DSM-OI2S |
S/W Option: DSM-OI2S |
|
dS-NET I/O Switcher | S/W Option as M1E | S/W Option: DSM-ODSNSW |
S/W Option: DSM-ODSNSW |
|
dS-NET VSIO Control | ||||
Port Access from scripts | S/W Option: DSM-OPTS |
|||
Event Manager | S/W Option: DSM-OEM |
|||
Digital I/O (max 192kHz) | ||||
BNC WCK Sync IN/OUT (For DO only) | ||||
Digital Carrier analysis - Comprehensive | ||||
Digital Carrier analysis - Basic Currently pending release |
Limited support provided As M1E option |
S/W Option: DSM-OCA1 |
Limited support provided As M1E option |
|
Digital Channel Status - Simple view | ||||
Digital Channel Status - FULL Detail | S/W Option: DSM-OCSF |
|||
Digital Carrier/sync monitor BNCs | ||||
Monitor Outputs on system unit (BNC, Headphone & Speaker) |
Via host PC audio. |
Via host PC audio. |
Via host PC audio. |
Via host PC audio. |
Monitor Outputs on host PC (Via PC audio out) |
||||
Core Signal Generator Functions Sine, Log Swept Sine, Twintone White/Pink noise |
||||
Advanced Signal Generator Functions Ramp, Pulse/Square, Tone burst, Bin centered tones, User waveforms |
S/W Option: DSM-OXSG |
Key features of dScope III M1 family
- Test electronics, speakers or microphones using dScope M1 internal phantom power;
- Measure analogue voltages to 100Vrms (Balanced) or 50Vrms (Unbalanced);
- Two independant Generator channels, up to >100kHz signal generation with analogue output levels up to +26dBu;
- Two independant Analogue Inputs with sampling rate up to 768kHz and useable bandwidth > 200kHz;
- Two low-residual, high-bandwidth analogue IO channels, with balanced and unbalanced operation;
- Two-channel digital IO, AES3 and S/PDIF modes with Channel Status support;
- Familiar dScope UI mirroring bench instruments
- Easy (no coding!) test automation based on your saved setups with "Auto Sequence"
- Custom scripting available with integrated coding environment, COM API and NI integration(COM);
- Measure speaker frequency response, acoustic phase response, THD & speaker impedance simultaneously using our script app;
- Minimal electro-mechanical components for long service life;
- Low power, <15W, via Sealed 12V AC-DC power converter;
- Light weight & small enough to pack in a briefcase; rack-mount kit available.
- Hook up directly to digital audio IC's with integrated I2S capability ("uVSIO");
- Enhanced automation with external triggers & control outputs with integral GPIO;
- Basic digital I/O carrier degradation and analysis (jitter);
Coming Soon pending software update:
M1 Software Download - UPDATED 2020-07-09
Download V1.50 if you have a dScope M1, M1E, M1D or M1HP interface unit similar to the one shown above. Although the 1.50 version can run with the original dScope Series III System Unit, it is not yet the recommended release for that unit as application support for many scripts and configurations from the web site and part of the default install are not yet adapted for the new version. dScope Series III System Unit users should download V1.45h from the main downloads page.dScope M1 family software download | |
Windows 7, 8/8.1 & 10 For 32 & 64-bit: | dScopeSetup_1_50_13_20200709.exe |
Mechanical
dScope M1 units are contained in a rugged metal case, small enough to be carried in a laptop bag, but which can also be rack-mounted in 1U with the optional racking ears if required.dScope M1 family | |
Dimensions: | 230 x 180 x 36mm (1U mounting kit available) |
Weight: | 1.3kg |
Supply voltage: | dScope IIIM1 interface :12V DC, 1.2A dScope IIIM1 interface + AC adaptor: 110/230V +/- 10%; 45Hz to 65Hz <15W (Note: AC Adaptor included) |
Power consumption: | dScope IIIM1 plus AC adaptor: <15W |
Operating temperature: | 5°C to 45°C |
Relative Humidity: | 80% non condensing |
Max Altitude | 2000 metres HAMSL |
Connectors
dScope M1 units have the following connectors and indicators (subject to software version spport as above):Front (left-to-right) | Rear (left-to-right) |
DO XLR, TOSLINK | Chassis ground (screw and 4mm) |
DI TOSLINK, XLR | BNC Wordclock I/O (NOTE: Only used with AES digital I/O) |
Bicolour power LED | dS-NET/GPIO/I2S DB9-M |
AO XLR A, B | RJ45 Ethernet (future option, may be omitted from initial production) |
AI XLR A, B | USB 2.0 B host interface |
2.5mm DC-IN (12V, 1A nominal) |
The AI and AO XLRs will accept RCAm-XLRm and RCAm-XLRf adapters which will connect the cold-leg to signal ground for unbalanced operation.
The DI and DO XLRs will accept RCAf-XLRm and BNCf-XLRf adapters for S/PDIF and AES-3id operation. The impedance of the interfaces will automatically be switched from 110R to 75R by their insertion, and the DO amplitude range available is selected in software according to fitment.
The DB9-M connector contains five IO connections which can be used either for GPIO purposes OR uVSIO (I2S) depending on settings in the dScope software. The functions of the 5 connections are detailed in the following table:
GPIO mode | uVSIO mode |
Input | Audio data Input |
Output | Audio data Output |
Programmable Input or Output | MCK |
2x Programable Input or Output (both will have same function). | SCK |
LRCK |
Additionally, the DB9 connector provides a connection for the Spectral Measurement dS-NET IO Switchers, enabling switching control of over 1000 audio channels.
NOTE: The dSNet-VSIO peripheral used with the alternative dScope Series III System Unit is NOT supported with the dScope M1 family.
These specifications are provisional and may be changed without notice.